*To Print, Click The PRINT Button On Your Web Browser*

Ken-Way Music-wire

(Left Hand wound)

Cable Installation Instructions

800.533.0551

 

Products Tech-Support Email

 

  1. When installing a cable in the Ken-Way Jr Electric Drain Cleaner, Check to see that the crank-arm cable guide turns freely before installing cable. This is extremely important for correct operation.

 

  1. Insert the cable into the crank-arm and push firmly into the back of the drum.  The    cable should coil into the drum in a CLOCKWISE direction, for Left Hand would cable.

 

  1. Secure the cable to the drum using the anchor clip inside the drum and fasten securely.  Approximately one inch of the cable should protrude past the tightened end of the anchor clip.

 

  1. Check frequently to ensure that the cable end is securely attached to the anchor clip.

 

  1. Feed new cable into drum using a back and forth motion, causing the cable to lie against the drum in nice flat even rows, not lose and sloppy.  Torque will feed back into the drum as obstructions are encountered during machine operation.  The torque will push the cable up against the drum wall.  When returning cable into the drum, make sure the cable feeds into the drum in even, tight rows, from back to front.  If a coil goes in unevenly, pull it back out and re-feed it.   Lose or overlapping cable in the drum may flip around and kink up during operation.  Remember the drum is not only a storage container for the cable- but an important functioning part of the machine.